The r900 is being produced for those who wish the tonometer to remain permanently on the slit lamp. It is mounted on a pivot on the microscope and for examination is swung forward in front of the microscope. A notch position ensures exact centring of the prism with the left objective. When not in use the instrument is secured in a notch position to the right of the microscope. Observation of the flattened area of the cornea is made through the left eye-piece only.
The illumination device is moved from the left until it just touches the tonometer support and in position the area of contact is illuminated through the prism and is free of reflection. Also there is more space to hold open the patients eye. The priveo support for the 900 tonometer also serves to hold the photographic attachment. When any of these are used the tonometer must first be lifted off its pivot.
Luna Plus Hand-held Digital Fundus Camera 16mp
$5,395.00
Vendor: EyeDirect Seller PartnerMicroclear Hand-held Digital Fundus Camera 16mp Luna Plus
Perfect for mission Trips and vision screenings. Hard case included.
Tags: Portable Device,Retinal Camera
Description
Microclear Hand-held Digital Fundus Camera 16mp Luna Plus
PRODUCT TECHNICAL PARAMETERS
FOV 45°
Transmission and storage interrnal capacity 16GB:USB/BT
Minimum pupil 2.5mm
Weight 560g
Refractive compensation -20D~+20D
Power supply lithium Battery 3.7V 3400mAh
Focus way Auto/ manual/real time auto focus
The battery continuously working time 6h( Standby time exceeds 24h)
Fixation targets 8 internal targets fixation
Image/Video format JPEG/3GP
Image resolution 1920×1080
Operating system PC: Windows system APP: Android
Screen 3. 97 inch TFT-LCD
ID Card reading and collection Support
Shoot type IR/White LED
NFC card reader Support
Model HFC
Connect function Professional software App support DICOM
Optional adapters :
Slit-lamp adapter —————————————–$ 350.00
Slit-lamp base system with Adapter ( as shown on brochure ) —— $ 1,695.00
Vendor Information
Athena Hand-held Vision Screener
$4,995.00 Vendor: EyeDirect Seller PartnerHand-held Vision Screener Athena
ADVANTAGES
1) Binocular diopter measurement.
2) Pupil diameter measurement.
3) Auto operation distance in 1 meter.
CHARACTERISTICS
1) Quick screening within 1 second.
2) Portable and light in weight.
3) Changeable and rechargeable battery.
4) Report output.
PRODUCT TECHNICAL PARAMETERS
Display screen Touch screen
Operating mode Binocular measurement
Refractive detection Auto
Working distance 1m
Pupil diameter Range: 2.0mm-9.0mm
Pupil distance Range: 35mm-80mm
Spherical Range:-6.0D~+3.0D Accuracy:±0.25D
Cylindrical Range:-0.00D~3.0D Accuracy:±0.50D
Detection time ≤1S
Axis Range:1°~180° Accuracy:±10°
Fixation target Light and sound
Others Applicable for different screening patterns in infants , children and adults
Hyperion Digital Photo Hand-held Slit Lamp
$3,995.00 Vendor: EyeDirect Seller PartnerDigital Photo Hand-held Slit Lamp Hyperion
High definition imaging
Real-time focus system
Real-time focus system
Cloud service system
Super light and convenient
Multi data transfer and storage system
Four storage modes:
1. Built-in 16G storage.
2. USB connect the computer and export.
3. Real-time Wifi, computer, mobile terminal and cloud transmission, as well as data analysis and software upgrading services.
4. Bluetooth download to Andriod only (Apple format is in development)
Easy operation and high definition imaging
1) Support cloud service system.
2) Real-time focus system.
PRODUCT TECHNICAL PARAMETERS
MAGNIFICATION 1OX
IMAGE/VIDEOFOVRMAT JPEG/3GP
WORKING DISTANCE 80mm
POWER 3.7VLithium Battery
SLIT WIDTH 0-12mm continuously adjustable
TRANSMISSION WiFi,BT
APERTURE DIAMETER 0.2mm,1mm,5mm,12mm
STORAGE Internal capacity 16GB
FILTER Heat-absorption, Red-free Cobalt blue
INTERFACE Micro USB
IMAGE RESOLUTION 16MP
SIZE 140mm(W)*118mm(D)*225mm(H)
LIGHT SOURCE White LED
N.W. 850g
SCREEN 3.97
PACKING SIZE 36*29*26 cm
i-Optik KR-9600 AutoRef/Keratometer
$4,995.00 Vendor: EyeDirect Seller PartnerModo de medición
K / R Medición de refracción / queratometría ÁRBITRO Medida de refracción KER Medición de la queratometría
Medida de refracción
Distancia vertical 0.0mm, 12.0mm, 13.75mm, 15.0mm
Esfera
-25.00 ~ + 22.00D (0.12 / 0.25Dsteps) (VD = 12mm) Cilindro 0.00 ~ ± 10.00D (0.12 / 0.25D pasos) Eje 0 ° ~ 180 ° (paso 1 °) Distancia del alumno 10 ~ 85mm Diámetro mínimo de la pupila Φ2.0mm Objetivo Objetivo de empañamiento automático
Medición de la queratometría (KR-9600)
Radio de curvatura 5 ~ 10mm (0.01mm pasos) Potencia refractiva 33.75D ~ 67.50D (0.12 / 0.25D pasos
Poder cilíndrico 0.00 ~ 15.00D (0.12 / 0.25D pasos
Eje 0 ° ~ 180 ° (pasos 1 °) Diámetro corneal 2.0 ~ 12.00mm
Especificación de hardware
Monitor Pantalla LCD a color de 7.0 pulgadas
Impresora
Impresora térmica de fácil carga y cortador automático. Ahorro de energía 5/15 minutos
Salida de datos RS232 / Bluetooth
Fuente de alimentación AC100 ~ 240V, 50 / 60HZ, 50W
Dimensión / Peso 262 (W) * 487 (D) * 467 (H) mm / 17.5 kg
Optimetrics Tonometer R900 style
$1,095.00 Vendor: EyeDirect Seller PartnerOptiLasa/Optimetrics R900 style Tonometer
Fits most Haag-Streit style Slit-lamps :
Appasamy, Burton, CSO, Ezer, Frye, Gilras, Haag-Streit, Han-Hiess, Huvitz, Inami, Kanghua, Keeler, Luxvision, Marco, Mediworks, Mentor, Nidek, Reichert, Topcon, Woodlyn, Veatch, Takagi, Viewlight.
The r900 is being produced for those who wish the tonometer to remain permanently on the slit lamp. It is mounted on a pivot on the microscope and for examination is swung forward in front of the microscope. A notch position ensures exact centring of the prism with the left objective. When not in use the instrument is secured in a notch position to the right of the microscope. Observation of the flattened area of the cornea is made through the left eye-piece only.
The illumination device is moved from the left until it just touches the tonometer support and in position the area of contact is illuminated through the prism and is free of reflection. Also there is more space to hold open the patients eye. The priveo support for the 900 tonometer also serves to hold the photographic attachment. When any of these are used the tonometer must first be lifted off its pivot.
i-Optik ARK-910 AutoRef/Keratometer
$6,995.00 Vendor: EyeDirect Seller PartnerAuto-Refractor/Keratometer
Specifications
Corneal curvature measurement (ARK-910 model only)
Others
Vista Vision FVD Acuity Chart
$2,495.00 Vendor: EyeDirect Seller PartnerVista Vision FVD (Far Vison Device)
– LCD 24” WIDE Screen, contrast 1000:1, calibrated luminance,
– Wall mounting and Portable, – Lifelong LCD calibrated and constant luminance,
– Completely silent (fan-less), – Fast built-on and instant-off (Embedded Linux Operating System),
– All letters chart with contrast sensivity function,
– Complete, precise and versatile software for a fast acuity evaluation; programmable patient’s acuity examination,
– Free internet upgrade software via USB Key, – Long-life, up to date technology and competitive price!
Related Products
Frey CP-400 Chart Panel
$1,925.00 Vendor: EyeDirect Seller PartnerFrey SL-100 w/ SLi-200
$12,250.00 Vendor: EyeDirect Seller PartnerMDT Acoustic Locator LA-1
$1,245.00 Vendor: EyeDirect Seller PartnerFrey Visual Field AP-250
$11,950.00 Vendor: EyeDirect Seller Partner